Private wells · United States
Match the lab report before you buy the filter.
AquiferFit is a well-water desk, not a storefront. It puts iron, sulfur, hardness, pH, bacteria, and pump flow into the only order that keeps the media alive, then prices the stack from verified records. The long form of that order is the well water filter guide.
Lab sheet
Private well reportLoad a sample if you want to see the machinery, or type a real report. The match updates as the sheet is completed. The numbers stay in this browser and are not submitted as a lab report.
Still needed: iron, hydrogen sulfide, manganese, hardness, pH, coliform, bathrooms, household size, pump flow.
The order below is the installation sequence. Stages stay unmarked until the sheet can be calculated.
- 0Lab testWaiting
SpringWell will not ship a well system without a lab report. A rust stain is not an iron number.
- 1Spin-down sedimentWaiting
Sand and grit hit this screen before they hit the media. It is the cheap stage that protects every expensive one.
- 2Calcite pH neutralizerWaiting
Only inside a narrow acid band. Calcite dissolves calcium carbonate and adds hardness, so it has to sit before the softener.
- 3Iron / hydrogen sulfide filterWaiting
Oxidation belongs here, while iron and sulfur are still dissolved, and before resin is asked to do a job it is bad at.
- 4Salt-based softenerWaiting
Hardness is the job, including hardness a calcite tank just added. Raw iron in front of this resin fouls it.
- 5UV sterilizerWaiting
Last, and only when the water at the quartz sleeve is already soft and low in iron. A fouled lamp does not disinfect.
SpringWell city-water systems (CF1 and CSS1) are not well-water iron and sulfur systems. Do not substitute them for WS1, WS4, WSSS1, or WSSS4. A city unit will not do the oxidation job a well filter is being asked to do.
Calcite hardness, salt use, and the lamp dollar amount are planning figures we publish, not shelf prices. The formulas are on the methodology page.
The well water filter guide
Whole-house systems side by side, the six-stage order, why a city carbon system is the wrong machine, the fail-closed limits, and the 1-year, 3-year, and 5-year cost are written out on the well water filter page. Every figure on it is a verified spec or a planning rule we publish. The matcher above is the same engine, pointed at your sheet.
Eight lab inputs the sheet will not invent
A stack is not calculated until these eight readings exist, plus household size and a bathroom tier. A stain color is not an iron number. An untested bacteria field is not a negative.
| Input | Unit | What it changes |
|---|---|---|
| Iron | ppm | Above 0.3 ppm, an oxidation filter is considered. The cap is the filter’s published cap, not the softener’s. |
| Hydrogen sulfide | ppm | Above 0.05 ppm, odor is treated as real. For the dissolved iron, manganese, and hydrogen sulfide on this site, 1 mg/L is treated as 1 ppm. |
| Manganese | ppm | Above 0.05 ppm, the oxidation stage has to publish a manganese rating. A blank cell is not a pass. |
| Hardness | GPG or ppm | Above 7 GPG, after any calcite addition, a salt softener is specified. 1 grain per gallon equals 17.1 parts per million, measured as calcium carbonate. |
| pH | pH units | The calcite window and the iron-filter window are different bands. Below the calcite window, chemical feed comes before any tank. |
| Coliform | negative, positive, or untested | Untested is not a pass. Positive is a well repair, not a filter SKU. A UV lamp is a later barrier with its own inlet limits. |
| Visible sediment | yes or no | Sand at the tap or in the toilet tank. The spin-down is still stage one on any stack the matcher will price. Urgency changes. The address does not. |
| Pump flow | GPM | GPM = gallons collected ÷ minutes. Measured at a hose bib while the pump is running, so the number is well yield rather than water already stored in the pressure tank. |
Iron, sulfur, manganese, and pH
Iron above 0.3 ppm, manganese above 0.05 ppm, or hydrogen sulfide above 0.05 ppm is what puts an oxidation filter on the order. pH decides whether that filter is allowed to see the water, and whether calcite is even eligible. For the dissolved iron, manganese, and hydrogen sulfide on this site, 1 mg/L is treated as 1 ppm.
Hardness, coliform, sediment, and flow
Hardness is the softener’s row, after any hardness calcite is about to add. Coliform is a word with three accepted results: negative, positive, or untested. Visible sediment flags sand. Pump flow is the backwash check. The report that can produce the chemistry rows, and the tests that cannot, is the well water test kit guide.
1 GPG equals 17.1 ppm
1 grain per gallon equals 17.1 parts per million, measured as calcium carbonate.
Divide a hardness result in ppm, or in mg/L as calcium carbonate, by 17.1 to get grains per gallon. The matcher’s unit toggle does the conversion and stores grains. A softener conversation in grains compared with a lab still in ppm is how a mild well gets sold a softener it does not need, or a hard well gets told it is fine.
What the toggle will not convert
Iron, manganese, and hydrogen sulfide stay in ppm. For the dissolved iron, manganese, and hydrogen sulfide on this site, 1 mg/L is treated as 1 ppm. Do not run those rows through the hardness factor.
The one-minute bucket test
Backwash is a yield, measured while the pump is running. GPM = gallons collected ÷ minutes. Water already sitting in the pressure tank will flatter a weak well and then the iron bed fouls.
- Use the hose bib closest to the pressure tank. Turn off every other faucet.
- Open the bib and let the pump start, so you measure well yield rather than a single tank of stored water.
- Collect water for 60 seconds in a bucket marked in gallons.
- The gallons you collect in that minute are the flow in GPM. A 5-gallon bucket that fills in 30 seconds is 10 GPM.
Where that GPM is used
The bathroom tier selects the backwash the media needs. Equal to the published figure passes. Below it, the equipment can still be priced and is marked do-not-order. The worked version is iron filter backwash flow rate.
Six stages, in the order that protects the media
Grit hits the screen before it hits a bed. Calcite, when the pH window allows it, sits before the softener because it adds hardness. Iron is oxidized before resin is asked to catch it. UV is last, and only when the water at the sleeve is already soft and low in iron. The reason each step exists:
- 0Lab testSpringWell will not ship a well system without a lab report. A rust stain is not an iron number.
- 1Spin-down sedimentSand and grit hit this screen before they hit the media. It is the cheap stage that protects every expensive one.
- 2Calcite pH neutralizerOnly inside a narrow acid band. Calcite dissolves calcium carbonate and adds hardness, so it has to sit before the softener.
- 3Iron / hydrogen sulfide filterOxidation belongs here, while iron and sulfur are still dissolved, and before resin is asked to do a job it is bad at.
- 4Salt-based softenerHardness is the job, including hardness a calcite tank just added. Raw iron in front of this resin fouls it.
- 5UV sterilizerLast, and only when the water at the quartz sleeve is already soft and low in iron. A fouled lamp does not disinfect.
City carbon is not one of the stages
SpringWell city-water systems (CF1 and CSS1) are not well-water iron and sulfur systems. Do not substitute them for WS1, WS4, WSSS1, or WSSS4. A city unit will not do the oxidation job a well filter is being asked to do. The city models are left out of the systems we review. The full comparison is the well water filter guide.
Limits that end the conversation
A packaged system is a published window, not a suggestion. The matcher will not round a lab up into the next brochure. The full reasoning sits on the methodology page.
Published windows, not rounded brochures
| Constraint | Published or planning value | Where it applies |
|---|---|---|
| SpringWell iron | ≤ 7 ppm | WS and WSSS, both bathroom tiers |
| SpringWell hydrogen sulfide | ≤ 8 ppm | WS and WSSS |
| SpringWell manganese | ≤ 1 ppm | WS and WSSS |
| SpringWell pH | 6.5–10 | Iron-filter window. Calcite can bridge the bottom edge. |
| Backwash, 1–3 baths | 5 GPM | WSSS1 |
| Backwash, 4–6 baths | 7 GPM | WSSS4 |
| Calcite | pH 6–6.5 | Below the window, chemical feed, not a bigger calcite tank |
| UV hardness | under 7 GPG | Strict inlet |
| UV iron | under 0.3 ppm | Strict inlet |
| UV tannins | under 0.1 ppm | Confirm on the lab. Not estimated. |
| SoftPro single-unit iron | 15 ppm | The 30 ppm marketing figure is not used |
| Kind hydrogen sulfide | ≤ 1 ppm | A low ceiling for rotten-egg water |
Where a standard system hands off
pH below the calcite window is soda-ash or another chemical feed, sized by a licensed local pro, before any media. Iron past the single-unit fallback is chemical injection designed locally. Hydrogen sulfide or manganese past the SpringWell cap has no verified substitute among the systems we review. Coliform-positive water is a well repair first. Those stops are tabulated on the well water filter page.
Start with the question you actually have
Whole house
The well water filter, in order
Verified systems, the stage sequence, the city-versus-well refusal, and the 1-, 3-, and 5-year cost from our verified specs.
Iron and sulfur
The softener is not the first tank
Why resin fouls when it is asked to be an iron filter, and when a combo is the cheaper honest buy.
Iron
Where the SpringWell cap stops
The published iron window, the backwash that keeps it honest, and the fallback that comes with a spec conflict.
The report
Read the rows that buy equipment
Iron, manganese, sulfur, hardness, pH, and coliform. The rest of the page is context, not a shopping list.