Method
The model is a refusal engine with a price tag.
Every threshold below is the value in the rules or product file. If those files change, this page changes with them.
Stage order
The sequence is the product. A softener downstream of untreated iron is a different, worse machine than the same softener downstream of a working oxidation filter. Calcite after the softener undoes the softener, because the mineral it dissolves is hardness. UV in front of iron and hardness is a quartz sleeve waiting to foul.
- 0Lab testSpringWell will not ship a well system without a lab report. A rust stain is not an iron number.
- 1Spin-down sedimentSand and grit hit this screen before they hit the media. It is the cheap stage that protects every expensive one.
- 2Calcite pH neutralizerOnly inside a narrow acid band. Calcite dissolves calcium carbonate and adds hardness, so it has to sit before the softener.
- 3Iron / hydrogen sulfide filterOxidation belongs here, while iron and sulfur are still dissolved, and before resin is asked to do a job it is bad at.
- 4Salt-based softenerHardness is the job, including hardness a calcite tank just added. Raw iron in front of this resin fouls it.
- 5UV sterilizerLast, and only when the water at the quartz sleeve is already soft and low in iron. A fouled lamp does not disinfect.
When a stage is added
A stage is added only when a result is above the level. Iron and manganese follow common US secondary maximum contaminant levels. Hydrogen sulfide uses a typical odor threshold. Hardness uses the common US hard-water cut. A result equal to the level does not, by itself, add a stage.
- Iron above 0.3 ppm.
- Manganese above 0.05 ppm.
- Hydrogen sulfide above 0.05 ppm.
- Hardness above 7 GPG after any calcite addition.
1 grain per gallon equals 17.1 parts per million, measured as calcium carbonate. For the dissolved iron, manganese, and hydrogen sulfide on this site, 1 mg/L is treated as 1 ppm.
Backwash
An iron filter that cannot backwash at the published rate keeps oxidized iron in the bed. Pressure drop rises, service flow falls, and the media stops being a filter. The matcher compares your measured pump flow with the backwash figure stored on the size that matches the bathroom tier. Equal to the requirement passes. Below it, the equipment can still be priced, and it is marked do-not-order.
The bucket test is a yield check at a hose bib while the pump is running, not a measurement of water already sitting in the pressure tank. GPM = gallons collected ÷ minutes.
Calcite and the hardness bump
Planning estimate for salt use only. Added hardness is (target pH minus measured pH) times grains per pH unit, capped. Real calcite dose depends on carbon dioxide and alkalinity, which a metals panel may not report. This is not a prediction of finished-water hardness.
Added grains = (target pH 7 − measured pH) × 8 GPG per pH unit, capped at 12 GPG. The bump is applied only when pH is inside the calcite product’s own window. It is added to the salt estimate because the softener will see it.
Salt and five-year cost
Planning constants for a metered residential softener. Gallons per person is a US indoor planning average, not a meter reading. Grains per pound is an efficient salt setting, not a figure copied from a SpringWell manual. The bag price is a national planning allowance for a 40 lb bag, not a verified retailer SKU.
Grains per year = people × 75 gallons/person/day × 365 × effective hardness in GPG. Pounds of salt = those grains ÷ 4,000. Bags = pounds ÷ 40. The bag allowance is $8. Usable capacity for the regeneration interval is 75% of the published grain rating. Five-year cost is the current equipment total plus five times the annual operating estimate.
UV inlet
Used only to test the UV inlet. A softener that is actually on the stack is assumed to leave about 1 GPG. An iron filter whose published cap covers the inlet iron is assumed to leave iron under the UV limit. These are checks, not certified effluent guarantees. If the filter is outside its cap, the raw iron is what reaches the lamp.
The lamp is specified only for a positive or untested coliform field, and only when estimated hardness at the sleeve is under 7 GPG and iron is under 0.3 ppm. Tannins must be under 0.1 ppm on the lab itself. The lamp replacement interval on the product record is 365 days. Planning allowance for one lamp per replacement interval. AquiferFit does not have a verified SpringWell replacement-lamp shelf price in this data set. The allowance is not shown as a product price. The allowance used in the annual figure is $120.
The SoftPro conflict
When iron is past the SpringWell cap and still inside the single-unit Iron Master figure, that unit can become the iron stage, with a separate softener if hardness calls for one. The higher marketing figure is stored beside it and is never the pass/fail number. Hydrogen sulfide and manganese ratings for that unit are not in the verified record, so a lab that also has those contaminants is labeled as unverified rather than quietly covered.
What is not modeled
- Arsenic, nitrate, lead, pesticides, and other health contaminants. A metals-and-odor panel is not a full health test.
- Tannins, except as a UV checklist item you confirm yourself.
- Pressure-tank drawdown, pipe diameter, or a backwash number the manufacturer did not publish in the records we keep.
- A guarantee of effluent. Inlet assumptions are checks against fouling, not a certified finished-water report.