Calculator

The lab sheet, sized.

Same engine as the homepage, with a URL you can bookmark or send. Guides link here with a sample already filled in. Change one number and the stack changes with it.

Lab sheet

Private well report
WL-1

Load a sample if you want to see the machinery, or type a real report. The match updates as the sheet is completed. The numbers stay in this browser and are not submitted as a lab report.

Bathrooms
Bacteria / coliform

Still needed: iron, hydrogen sulfide, manganese, hardness, pH, coliform, bathrooms, household size, pump flow.

The order below is the installation sequence. Stages stay unmarked until the sheet can be calculated.

  1. 0Lab testWaiting

    SpringWell will not ship a well system without a lab report. A rust stain is not an iron number.

  2. 1Spin-down sedimentWaiting

    Sand and grit hit this screen before they hit the media. It is the cheap stage that protects every expensive one.

  3. 2Calcite pH neutralizerWaiting

    Only inside a narrow acid band. Calcite dissolves calcium carbonate and adds hardness, so it has to sit before the softener.

  4. 3Iron / hydrogen sulfide filterWaiting

    Oxidation belongs here, while iron and sulfur are still dissolved, and before resin is asked to do a job it is bad at.

  5. 4Salt-based softenerWaiting

    Hardness is the job, including hardness a calcite tank just added. Raw iron in front of this resin fouls it.

  6. 5UV sterilizerWaiting

    Last, and only when the water at the quartz sleeve is already soft and low in iron. A fouled lamp does not disinfect.

SpringWell city-water systems (CF1 and CSS1) are not well-water iron and sulfur systems. Do not substitute them for WS1, WS4, WSSS1, or WSSS4. A city unit will not do the oxidation job a well filter is being asked to do.

Calcite hardness, salt use, and the lamp dollar amount are planning figures we publish, not shelf prices. The formulas are on the methodology page.

How to fill the eight lab inputs

The form will not calculate while a required field is empty. Household size and the bathroom tier are the house. The eight rows below are the water and the well. Type the lab’s number, not a description of the stain.

Eight lab inputs. Household size (1–8 people) and the bathroom tier scale salt and pick the service-flow size. They are not concentrations, and they are still required before a stack is calculated.
InputUnitWhat it changes
IronppmAbove 0.3 ppm, an oxidation filter is considered. The cap is the filter’s published cap, not the softener’s.
Hydrogen sulfideppmAbove 0.05 ppm, odor is treated as real. For the dissolved iron, manganese, and hydrogen sulfide on this site, 1 mg/L is treated as 1 ppm.
ManganeseppmAbove 0.05 ppm, the oxidation stage has to publish a manganese rating. A blank cell is not a pass.
HardnessGPG or ppmAbove 7 GPG, after any calcite addition, a salt softener is specified. 1 grain per gallon equals 17.1 parts per million, measured as calcium carbonate.
pHpH unitsThe calcite window and the iron-filter window are different bands. Below the calcite window, chemical feed comes before any tank.
Coliformnegative, positive, or untestedUntested is not a pass. Positive is a well repair, not a filter SKU. A UV lamp is a later barrier with its own inlet limits.
Visible sedimentyes or noSand at the tap or in the toilet tank. The spin-down is still stage one on any stack the matcher will price. Urgency changes. The address does not.
Pump flowGPMGPM = gallons collected ÷ minutes. Measured at a hose bib while the pump is running, so the number is well yield rather than water already stored in the pressure tank.

Odor buttons are a placeholder

The hydrogen sulfide helpers fill the field with a starting ppm so you can see the stack move. They are not a lab. Replace them when the report arrives. Which tests can produce that report is the well water test kit guide.

Coliform has three states

Negative, positive, and untested. Untested keeps the kit in the plan and leaves it out of the equipment total, because SpringWell credits that kit toward a well system. Positive does not become a UV order by itself. The well gets fixed and retested first.

Hardness units: 1 GPG = 17.1 ppm

1 grain per gallon equals 17.1 parts per million, measured as calcium carbonate.

Leave the toggle on the unit the lab printed. A value entered as ppm is divided by 17.1 before it is stored as grains. Switching the toggle converts the number already in the box, so you do not divide twice. For the dissolved iron, manganese, and hydrogen sulfide on this site, 1 mg/L is treated as 1 ppm. Iron and manganese do not use the 17.1 factor.

The softener cut is in grains

Above 7 GPG, after any calcite addition, a salt softener is specified. A result equal to that cut does not, by itself, add the softener. The UV inlet is stricter: hardness at the sleeve has to be under the lamp’s limit, and equal fails.

Measuring pump flow with a one-minute bucket

GPM = gallons collected ÷ minutes. The field wants GPM. The bucket is how you get it without confusing stored tank water for well yield.

  1. Use the hose bib closest to the pressure tank. Turn off every other faucet.
  2. Open the bib and let the pump start, so you measure well yield rather than a single tank of stored water.
  3. Collect water for 60 seconds in a bucket marked in gallons.
  4. The gallons you collect in that minute are the flow in GPM. A 5-gallon bucket that fills in 30 seconds is 10 GPM.

Equal passes, and short does not

The bathroom tier you select loads the backwash figure for that size. A measured flow below it prices the equipment and marks it do-not-order. Oxidized iron would stay in the bed. The longer explanation is iron filter backwash flow rate.

What the six stages are doing

The result lists stages in installation order. A stage marked specified is the one the lab called for. A stage marked stopped is a limit, not a suggestion to buy a larger tank. The sequence:

  1. 0
    Lab test
    SpringWell will not ship a well system without a lab report. A rust stain is not an iron number.
  2. 1
    Spin-down sediment
    Sand and grit hit this screen before they hit the media. It is the cheap stage that protects every expensive one.
  3. 2
    Calcite pH neutralizer
    Only inside a narrow acid band. Calcite dissolves calcium carbonate and adds hardness, so it has to sit before the softener.
  4. 3
    Iron / hydrogen sulfide filter
    Oxidation belongs here, while iron and sulfur are still dissolved, and before resin is asked to do a job it is bad at.
  5. 4
    Salt-based softener
    Hardness is the job, including hardness a calcite tank just added. Raw iron in front of this resin fouls it.
  6. 5
    UV sterilizer
    Last, and only when the water at the quartz sleeve is already soft and low in iron. A fouled lamp does not disinfect.

Why the order is the protection

The screen takes sand before media can channel. Calcite, inside its own pH window, adds hardness the softener then has to remove. The iron and sulfur filter sits ahead of resin so the resin is not the iron filter. UV is last because a fouled sleeve does not disinfect. The equipment those stages map to is the well water filter guide.

Boundaries the result will not cross

This page will not diagnose a medical condition, shock-chlorinate a well, or design a chemical-feed system. Coliform-positive water is a call to your local health department or a licensed well contractor. pH below the calcite window, and iron past the single-unit fallback, are the same kind of stop: a local pro, not a larger tank.

The windows, in one table

Limits this desk will not stretch. A stage is added only when a result is above the level. Iron and manganese follow common US secondary maximum contaminant levels. Hydrogen sulfide uses a typical odor threshold. Hardness uses the common US hard-water cut. A result equal to the level does not, by itself, add a stage.
ConstraintPublished or planning valueWhere it applies
SpringWell iron≤ 7 ppmWS and WSSS, both bathroom tiers
SpringWell hydrogen sulfide≤ 8 ppmWS and WSSS
SpringWell manganese≤ 1 ppmWS and WSSS
SpringWell pH6.5–10Iron-filter window. Calcite can bridge the bottom edge.
Backwash, 1–3 baths5 GPMWSSS1
Backwash, 4–6 baths7 GPMWSSS4
CalcitepH 6–6.5Below the window, chemical feed, not a bigger calcite tank
UV hardnessunder 7 GPGStrict inlet
UV ironunder 0.3 ppmStrict inlet
UV tanninsunder 0.1 ppmConfirm on the lab. Not estimated.
SoftPro single-unit iron15 ppmThe 30 ppm marketing figure is not used
Kind hydrogen sulfide≤ 1 ppmA low ceiling for rotten-egg water

City models are not a fallback

SpringWell city-water systems (CF1 and CSS1) are not well-water iron and sulfur systems. Do not substitute them for WS1, WS4, WSSS1, or WSSS4. A city unit will not do the oxidation job a well filter is being asked to do. If the result stops, the methodology page is the formula, and how to read a well lab is the sheet you started from.